Salamander Pump Fault Finder
This page is specifically designed to assist in finding any faults relating to Salamander pumps.
- FAULT FINDER
- Salamander Positive Head Pumps
Start Here
- FAULT
- Pump will not start.
- Reduced performance or flow
- PROBABLE CAUSE
- Air in pump or system.
- SOLUTION
- Check that pump and pipe work is primed of all air.
- Check that the hot supply to the pump is fitted with the correct flange fitted to the hot water cylinder.
- Check that pump and pipe work is installed and plumbed in as per installation instructions, these can be downloaded by clicking here.
- Inlet filters blocked.
- AV couplers bent or distorted.
- Excessive hot temperature.
- Pump starts when not in use.
- PROBABLE CAUSE
- Air in system.
- Leak in pipe work.
- Noisey pump.
- Leaking pump.
- FAULT FINDER
- Salamander Negative Head Pumps
Start Here
- FAULT
- Electrical problem
- Pump Set In Wrong Mode
- Warning LED light lit
- Which LED is Illuminated?
- LED Light 1
- LED Light 2
- Aeration - Starvation Mode
- Check that the cold water storage tank is correct for installation and pump is fitted as per Salamander Installation instructions
- Check that there is a flange fitted to the hot water cylinder
- If fitted above the outlet to the hot water cylinder check that an anti-gravity loop has been plumbed in
- LED Light 3
Our many years of experience have shown that a majority of issues arise from badly planned installations.
We strongly recommend you double check that your Salamander product has been correctly installed in accordance with their guidelines and instructions.
If you require any further technical assistance please call Salamander on 0845 377 9160